Flammability (ASTM D-635) | Self Extinguishing |
Fungus & Bacteria Growth (MIL-F-52505 4.4.2.11) | Will not support growth of fungus or bacteria when subjected to mildew and bacteria tests. |
Hardness (ASTM D-2240) | 80 to 85 Shore D |
Bond Strength to Concrete (ACI COMM 503, Bulletin 59-43) | 300 psi (100% concrete failure) |
Resistance to Elevated Temperature (MIL-D-3134F 4.7.4) | No slip or flow at required temperature of 158F |
Coefficient of friction (ASTM D-2047) | 0.8 |
Water Absorption (ASTM C-413) | 0.5% |
Thermal Shock Resistance (ASTM C-884) | Passes |
Impact Resistance (MIL-D-3134F 4.7.3) | Withstands 16 ft/lb without cracking, delamination, or chipping. |
Minimum Compressive Strength (ASTM C-579, 7 Days) | 14000psi |
Tensile Strength (ASTM C-307) | 5500psi |
Thermal Coefficient of Expansion (ASTM C-531) | 28 x 10-4 |
Flexural Modulus of Elasticity (ASTM C-580) | 970,000 psi minimum at 7 days |
Maximum Shrinkage (ASTM C-531) | 0.5% |
Maximum Flame Spread Index (ASTM E-162) | 25 |
Pot Life | 20 to 25 minutes at 75F |
Re-Coat | 12 to 16 hours at 75F |
Light Service | 24 hours at 75F |
Mixing Ratio | 2 Parts A to 1 Part B by Volume |
Volatile Organic Content (VOC) | -0- |
Key Advantages | |
|
|
Key Considerations | |
|
|
Composition | |
100% Solids Epoxy and Modified Cycloaliphatic Amines with a variety of graded ceramic and conductive fillers.
Also available as KEY CONDUCTIVE NOVOLAC for superior performance and chemical resistance. |
|
Surface Preparation | |
Surface Preparation is the most critical portion of any successful resinous flooring system application. All substrates must be properly prepared as outlined in KEY RESIN COMPANY’S TECHNICAL BULLETIN 1. Work must be performed by trained or experienced contractors or maintenance personnel. The KEY RESIN COMPANY service department is pleased to answer any questions. | |
Installation | |
KEY CONDUCTIVE is carefully spread with a cement finishing trowel in one direction. Two coats of KEY CONDUCTIVE are required for every installation. The application of the second coat is applied in the direction perpendicular to the first coat. Consult your KEY REPRESENTATIVE for specific installation instructions. | |
Clean Up | Clean skin with soap and water. Tools and equipment should be cleaned with xylene or lacquer thinner. |
Coverage | |
Two coats of KEY CONDUCTIVE will yield approximately 50-60 mils when spread at 50 ft2 per gallon per coat.
KEY CONDUCTIVE MORTAR is trowel applied at 3/16 – 1/4 inch thick. |
|
Color Selection | |
KEY CONDUCTIVE is available in Key Standard Colors and Custom Colors as approved.
KEY CONDUCTIVE MORTAR is available in Black only. |
|
Availability | |
Key Resins are available throughout the United States, Canada, and a number of other countries. Contact the KEY REPRESENTATIVE in your area for details. | |
Maintenance | |
After completing the application of KEY CONDUCTIVE, the installer should provide the owner with maintenance instructions. KEY CONDUCTIVE is easily cleaned with neutral soaps or detergents. | |
Technical Service | |
Key Resin Company and KRC Associates, Inc. provide services and consultations on material selection, specification, troubleshooting, and other information on the proper repair and protection of concrete surfaces. KEY REPRESENTATIVES are available to assist you at any time. | |
Warranty | |
Key Resin Company (“Key”) warrants for a period of one (1) year that its products will be free of manufacturing defects and will be in conformity with published specifications when handled, stored, mixed and applied in accordance with recommendations of Key. If any product fails to meet this warranty, the liability of Key will be limited to replacement of any non-conforming material if notice of such non-conformity is given to Key within (1) one year of delivery of materials. Key may in its discretion refund the price received by Key in lieu of replacing the material. No customer, distributor, or representative of Key is authorized to change or modify the published specifications of this warranty in any way. No one is authorized to make oral warranties on behalf of Key. In order to obtain replacement or refund the customer must provide written notice containing full details of the nonconformity. Key reserves the right to inspect the non-conforming material prior to replacement. EXCEPT FOR THE EXPRESSED WARRANTY STATED ABOVE, THERE ARE NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR PURPOSE. KEY’S OBLIGATION SHALL NOT EXTEND BEYOND THE OBLIGATIONS EXPRESSLY UNDERTAKEN ABOVE AND KEY SHALL HAVE NO LIABILITY OR RESPONSIBILITY TO THE PURCHASER OR ANY THIRD PARTY FOR ANY LOSS, COST, EXPENSE, DAMAGE OR LIABILITY, WHETHER DIRECT OR INDIRECT, OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. |
Key Conductive Floor Coating
KEY CONDUCTIVE is a two component, 100% solids epoxy floor coating that utilizes the latest in conductive industrial floor coatings technology. Able to be installed as a coating or as a component to KEY MORTAR SL and KEY MORTAR STD, KEY CONDUCTIVE provides a chemical resistant, conductive surface for use in electronic component plants, paint and solvent storage areas, ammunitions facilities, or hazardous materials storage areas.
We have other products and systems of which we can Engineer to fit your application. Give us a call at 801-977-0508!