Components | 2 |
Visual Appearance | High Gloss |
Density | 1.6 |
Solids by Weight | 100 percentage |
pH Range | 2.5 – 14.0 |
Inorganic Acids | Very Good |
Organic Acids | Very Good |
Alkalis | Excellent |
Solvents | Very Good |
Hydrocarbons | Excellent |
Max. Dry Operating Temperature | 375 F |
Functional Cure | 36 hours |
Full Cure | 120 hours |
Repair System | SAR |
Surface Prep | SSPC-10 |
Adhesion | Excellent |
Flexibility | Good |
Pot Life at 70 F | 45 min. |
Equipment | Trowel, Gun, Squeegee |
Number of Coats | 2-1 |
Theoretical Coverage Per Gallon | 40 mil. sq. ft. |
Film Thickness Per Coat | 30 mils min. 90 mils max. |
Maximum DFT | 250 mils |
Recoat Time at 70 F | 36 hours max. 6 hours min. |
Min. Application Temperature | 55 F |
Mixing Ratio by Weight | 2:1 (B/A) |
Mixing Ratio by Volume | 2:1 (B/A) |
Dry to Touch | 6 hours |
Force Curing | |
Force cures are recommended for severe service conditions as both physical and chemical properties are enhanced. Force curing should not start until material has firmly set. Contact DUROMAR for specific instructions. | |
Storage | |
Force cures are recommended for severe service conditions as both physical and chemical properties are enhanced. Force curing should not start until material has firmly set. Contact DUROMAR for specific instructions. | |
Handling and Safety | |
Warning Eye and skin irritant. May cause dermatitis and sensitization. Always read and understand the product MSDS. Avoid contact with eyes, skin or clothing. Avoid breathing vapor, mist or spray. Use with good ventilation. | |
First Aid | |
In case of contact: Eyes: Immediately flush with water for at least 15 minutes. Skin: Immediately remove from skin with dry cloth followed by thorough washing with soap and water. Inhalation: Remove to fresh air. If breathing is difficult, give oxygen. Ingestion: Give large quantity of milk or water, induce vomiting. Contact a physician immediately. |
2131 High Performance Lining
General Description
DUROMAR HPL-2131 is a trowelable material, which is designed to rebuild and/or protect tanks subject to severe erosion and corrosion. It is best applied using a mastic or grout pump.
Chemical Description
Multi-functional epoxy with a uniquely modified polyamide hardener.
We have other products and systems of which we can Engineer to fit your application. Give us a call at 801-977-0508!